ABB E-mobility, Siemens and BYD Compete in the 1 MW EV Charging Race
ABB E-mobility, Siemens, Kempower, BYD and 11 rivals push EV charging toward 1.5 MW as public networks pass 7 million points and reliability complaints persist.
- Section
- Construction Tech
- Author
- By Grace Kim
- Filed
- Length
- 5 min read
Key takeaways
- Global public EV charging points exceeded 7 million at the end of 2025, following 1.8 million additions.
- Siemens’ SICHARGE FLEX spans 480 kW to 1,680 kW; Alpitronic’s HYC1000 shares 1,000 kW across eight vehicles.
- Kempower reported €251.3 million in 2025 revenue and €303.5 million in order intake.
- Which’s Zapmap survey results showed 75 percent of en-route problem experiences involved a charger not working.
- The IEA projects more than 520,000 Indian charging points under Current Policies and approximately 1.2 million under Stated Policies by 2035.
Global public EV charging infrastructure exceeded 7 million points at the end of 2025, after nearly 1.8 million additions during the year, according to the International Energy Agency’s Global EV Outlook 2026. China accounted for more than 65 percent of the global total, while India had approximately 88,000 points, the IEA reported.
GreenTechLead’s 2026 review of 15 suppliers describes a race beyond 400 kW, with systems rated up to 1.68 MW. The manufacturers compete on charging speed, efficiency, manufacturing costs and reliability. Electric trucks, modular power distribution, liquid cooling and battery integration shape the current product cycle.
Megawatt systems reshape the equipment field
GreenTechLead lists the following manufacturer specifications.
- ABB E-mobility: The A400 offers 200, 300 and 400 kW, two outlets, dynamic sharing in 50 kW increments and reported efficiency up to 97 percent. GreenTechLead calculates that 100 kWh delivered needs about 103.1 kWh of input, excluding site losses.
- Alpitronic: The HYC1000 provides 1,000 kW across up to eight vehicles in 62.5 kW increments. Its Megawatt Charging System supports 1,500A for electric trucks. The outlets share capacity and cannot each deliver 1 MW simultaneously.
- Kempower: The Mega Satellite Flex supports 1.2 MW MCS and up to 560 kW through CCS. Kempower reported 2025 revenue of €251.3 million, €303.5 million in order intake and a €141.3 million backlog. Revenue reached €201.7 million in January–September 2026, while third-quarter revenue fell 10 percent year over year. GreenTechLead notes that these are company-wide figures, not megawatt-charger revenue.
- Delta Electronics: The company combines EV charging with power conversion, energy storage and energy management for passenger vehicles, commercial properties and fleet depots. GreenTechLead says battery-integrated charging can reduce peak grid demand, but savings depend on tariffs, storage costs and utilisation.
- Siemens: SICHARGE FLEX offers 480 kW to 1,680 kW, current up to 1,500A and dynamic distribution across outlets. Siemens announced its first commercial deployment at an OMV charging location in Austria in September 2026.
- SK Signet: The company supplies DC fast chargers up to 400 kW for public networks, highways and fleets. Its North American business depends on deliveries, connector compatibility, maintenance and warranty performance. Actual speed varies with vehicle voltage and battery limits.
- Star Charge: The Nova V4 offers 480 kW and 720 kW configurations, up to 12 outputs and 97 percent peak efficiency. Distributed architecture lets operators share capacity instead of installing separate power systems for each outlet.
- Autel Energy: The DC HiPower provides up to 640 kW, delivering 480 kW to one vehicle or 320 kW each to two. The system combines hardware, management software and remote diagnostics.
- Ekoenergetyka: The Poland-based supplier serves electric buses, fleets and public networks. Its Axon Easy DLBS platform offers 160, 240, 320 and 400 kW. Dynamic load balancing supports scheduled fleet charging and shared electrical capacity.
- Power Electronics: The Megawatt Charging System delivers up to 1,440 kW of continuous power and 1,500A of current. It supports one to four outputs, depending on configuration, for electric trucks, buses and commercial depots needing more energy than passenger-car chargers.
- BTC Power: The fourth-generation all-in-one DC charger provides 320 kW through two 160 kW outputs. It operates up to 1,000V DC with modular power stacks and supports OCPP 1.6J and OCPP 2.0.1.
- Exicom: The Indian manufacturer inaugurated a Hyderabad manufacturing facility in March 2026 after investing ₹216 crore. The plant targets 2.5 times Phase I production capacity and more than 750 direct jobs. It produces EV chargers, battery packs and power electronics.
- Huawei Digital Power: FusionCharge combines liquid-cooled high-power charging with digital energy management. Huawei’s portfolio supports solar generation and battery storage. Liquid cooling manages heat in high-current equipment and cables.
- XCharge: GridLink combines a 215 kWh LFP battery with up to 194 kW of DC output. Its approximately 44 kW AC input allows temporary output above the grid connection’s continuous capacity. Storage investment, battery degradation and conversion losses affect profitability.
- BYD: FLASH technology supports up to 1,500 kW for compatible vehicles. BYD reported 4,239 charging stations in China by March 5, 2026. GreenTechLead called its target of 20,000 stations by year-end “a deployment goal, not confirmed completed capacity.”
Driver complaints expose network gaps
Which reported findings from Zapmap’s 2025 charging survey of drivers who experienced problems:
- Charger not working: 75% en-route and 68% destination
- Insufficient chargers: 51% and 49%
- Payment unavailable: 30% and 29%
- Charging too expensive: 29% and 31%
- Power below advertised level: 25% and 20%
These percentages describe surveyed problem experiences, not the failure rate of all chargers, Which said.
The J.D. Power 2025 US EV Public Charging Study found that 14 percent of surveyed EV owners visited a public charger without successfully charging. DC fast-charging satisfaction fell 10 points to 654 out of 1,000.
Because the complaints involve equipment, payment platforms and network operations, the studies cannot automatically be attributed to individual manufacturers.
Efficiency changes the cost calculation
GreenTechLead calculates that a DC charger at 97 percent efficiency requires approximately 1.031 GWh of electricity to deliver 1 GWh. At 94 percent efficiency, input rises to approximately 1.064 GWh.
GreenTechLead puts the difference at approximately 32,900 kWh annually, equivalent to ₹2.63 lakh at an illustrative ₹8/kWh electricity price.
At 20 percent average power utilisation, theoretical annual electricity delivery is:
- 150 kW: 262,800 kWh
- 400 kW: 700,800 kWh
- 1,000 kW: 1,752,000 kWh
The calculations exclude downtime, charging taper and site-specific constraints, GreenTechLead said.
India’s 2035 build-out
The IEA projects that India’s public charging network could exceed 520,000 points by 2035 under its Current Policies Scenario. That path requires approximately 43,000 annual additions.
The IEA’s Stated Policies Scenario projects approximately 1.2 million points by 2035.
India’s PM E-DRIVE programme allocates ₹2,000 crore for charging infrastructure, creating opportunities for domestic manufacturers such as Exicom and international suppliers.
What does this change for operators?
GreenTechLead expects manufacturers to compete in 2027 on reliability, charging efficiency, confirmed orders, manufacturing costs, warranty performance and after-sales service rather than maximum advertised power alone. For operators, uptime and service support matter as much as headline kilowatts.
Source: greentechlead.com
More from Grace Kim
Show full bio
Staff writer covering money, funding and market shifts around construction industry, architecture, interior design at Built Current.
379 articles